The following table contains known issues, scheduled bug fixes, and feature improvements for the SMARC Development Board.
For other information, click on the below links:
Customer Impact: The system fails to reliably detect over current events causing USB hub to not consistently shut down a faulty device or not report the fault correctly.
Description: The OC pulse generated by the protection circuit is too short, so the USB hub cannot detect the overcurrent condition. As a result, proper shutdown or protection does not occur.
Workaround: There is no identified workaround. The issue will be fixed in the next board revision.
Customer Impact: Customers can not use Toradex DSI to LVDS Adapter with SMARC Development Board.
Description: The C4 capacitor of the Toradex DSI to LVDS adapter is to high and collides with the DP connector on SMARC Development Board.
Workaround: There is no available workaround. Issue was fixed on SMARC Development Board V1.2.
Customer Impact: The CSI0 Interface is not working on SMARC Development Board V1.1.
Description: CSI0 Interface is not operational due to inverted DSI0_D0 and DSI0_D1 signal pair.
Workaround: There is no available workaround. Issue was fixed in SMARC Development Board V1.2.