The following table contains known issues, scheduled bug fixes, and feature improvements for the Ivy and Ivy Plus Carrier Board.
For other information, click on the below links:
Customer Impact: Device may exhibit unstable or unwanted behavior at input voltages below 11V. Minimum Input Voltage should be considered 11V instead of 8V.
Description: It's not possible to draw 3A from the 5V rail with an input voltage of 8V.
Workaround: Recommended input voltage should be higher than 11V. It will be fixed in the next version of the Ivy Plus.
Customer Impact: High overshoot at the 5V rail of over 5% during the transient load test.
Description: During transient load testing, the 5V rail exhibits a high voltage overshoot exceeding 5%. This occurs when the load changes rapidly, and the power supply momentarily outputs a voltage higher than the intended 5V + 5% before stabilizing.
Workaround: No work around available in the current version. The issue will be fixed in the next version.
Customer Impact: The UART_4 interface of the connected SoM is not available on the carrier board.
Description: There is no connector available for UART_4. The signals are not routed from the SoM connector.
Workaround: No workaround available in the current version. The UART_4 interface will be provided in the next version.