The following table contains known issues, scheduled bug fixes, and feature improvements for the Clover Carrier Board.
For other information, click on the below links:
Customer Impact: Customers who need UART_3 on J2 at 3.3 V logic level cannot use it directly from the carrier board.
Description: UART_3 signals are not available as 3.3 V signals on connector J2 on affected Clover carrier boards. The original UART_3 3.3 V level-shifter implementation on Clover carrier boards affected the recovery-mode strapping signals. To avoid impacting recovery mode operation, the onboard UART_3 3.3 V level-shifter circuit was removed, and UART_3 3.3 V signals are therefore no longer available on connector J2. Proper level-shifter was implemented in Clover V1.2 revision.
Workaround: Use an externally connected voltage-level converter to access UART_3 from connector J21 at the required 3.3 V logic level.
Customer Impact: Ethernet Interface - ETH2 - does not work.
Description: The ETH_2_XGMII signal lines are swapped, resulting in the ETH2 interface being non-functional.